Part Number Hot Search : 
MC74HC B431LBK3 45984 P4840 C18F44 AMC71 307C1545 36766
Product Description
Full Text Search
 

To Download SUINT2200RTXL2UA Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  smartonline 200-240v 2.2kva 1.6kw on-line double-conversion ups, extended run, snmp, webcard, 2u rack/tower, usb, db9 serial model number: SUINT2200RTXL2UA description 2200va on-line, double-conversion ups system for critical server, network and telecommunications equipment. 2u rackmount form factor with an installed depth of only 483 mm. expandable battery runtime with optional bp48v24-2u and bp48v60rt-3u external battery packs. full-time sine wave 200/208/220/230 or 240v +/-3% output. online, double-conversion uninterruptible power supply (ups) actively converts raw incoming ac power to dc, then re-converts output back to completely regulated, filtered ac output. operates continuously without using battery power during brownouts to 130v and overvoltages to 275v. highly efficient operation in optional economy mode setting, saving btu heat output and energy costs. c20 inlet input connection; 2 c19 and 4 c13 output receptacles. network-grade ac surge and noise suppression. zero transfer time between ac and battery operation. network management interfaces support simultaneous communications via usb port, db9 serial port and snmpwebcard slot. hid-compliant usb interface enables integration with built-in power management and auto shutdown features of windows and mac os x. supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. includes poweralert monitoring software and complete cabling. emergency power off (epo) interface. integrated 2-bank pdu switching supports load shedding and remote-reboot of connected equipment. 3-stage metered current monitoring and battery charge status leds. led display panel easily rotates for better viewing in rackmount or tower configurations. dataline surge suppression for dialup, dsl or network ethernet connection. utility power and voltage regulation leds. audible alarm. self-test. fault-tolerant auto-bypass mode. 4-post rackmount accessories included; 2-9ustand tower kit and 2postrmkitwm two post rack & wallmount accessories available. field-replaceable, hot-swappable internal batteries and external battery packs. attractive all-black color scheme. features smartonline high performance ups system is ideal for critical voice, data, medical and industrial network applications true on-line, double-conversion ups provides perfectly regulated sine wave output within 3% of 200/208/220/230/240v (user selectable) under all usage condition maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time highlights 2200va / 2.2kva / 1600 watt on-line double-conversion 2u rack/tower ups 200/208/220/230/240v 50/60hz output; high efficiency economy mode option expandable runtime; hot-swap batteries; 19 in / 48.3cm installed depth usb, rs232 & epo ports; support for snmp/web card options front panel status leds with detailed load and battery metering 2 independently switchable output load banks c20 inlet; c19 & c13 outlets, 1 c19 to c20 & 2 c13 to c14 power cables included package includes SUINT2200RTXL2UA smartonline double-conversion ups system poweralert software with usb and serial cabling mounting hardware for 4 post rack enclosures power cables: (1) c19 to c20 and (2) c13 to c14 instruction manual with warranty information 1 / 6
removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other ups types corrects line voltage conditions as low as 130v and as high as 275v back to selectable 200/208/220/230/240v (+/-3%) values highly efficient operation in optional economy mode setting, saving btu heat output and energy costs. standard internal battery set offers 14 minutes runtime at half load (800w) and 5 minutes at full load (1600w) extended runtime with bp48v24-2u (limit 1), bp48v60rt-3u (multi-pack compatible) and bp48v27-2us (multi-pack compatible) external battery packs some external battery configurations require the use of tripp lite's external battery configuration software (see manual) compact rackmount form factor installs using only 2 rack spaces (2u) with a maximum installed depth of only 483 mm ships with all mounting accessories for 4 post rackmount installation optional 2postrmkitwm enables 2 post rackmount or wallmount installation optional 2-9ustand accessory enables small-footprint upright tower placement fault tolerant electronic bypass maintains utility output during a variety of ups fault conditions network interfaces support simultaneous communications via built-in usb, db9 serial and snmpwebcard slot hid compliant usb interface enables integration with built-in power management and auto shutdown features of windows and mac os x included poweralert ups monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over ip ups interface supports on-battery, low-battery, power-restored, ac-voltage, dc-voltage, output current monitoring, battery charge current, battery capacity, ac line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, ups nominal voltage adjustment and ups line to battery power voltage setpoints built-in emergency power off (epo) interface with cable c20 inlet power connection / c19 and c13 output receptacles c20 inlet accepts user-suppplied ac power cord with country-specific plug includes 2 c13 to c14 and 1 c19 to c20 output power cables integrated 2 bank switched pdu enables remote outlet management for load shedding or remote reboot of individual load banks (both of the c19 outlets are individually controllable) front panel leds offer current monitoring and battery charge level information ups ships fully assembled in full compliance with dot regulations, no time consuming connection ofinternal batteries by user required single line tel/dsl or network ethernet line surge suppression specifications output output volt amp capacity (va) 2200 output kva capacity (kva) 2.2 output watt capacity (watts) 1600 output kw capacity (kw) 1.6 power factor 0.7 crest factor 3:1 nominal output voltage(s) supported 200v; 220v; 230v; 240v nominal voltage details 230v default frequency compatibility 50 / 60 hz 2 / 6
frequency compatibility details output frequency matches input nominal on startup, defaults to 50 hz on cold-start output voltage regulation (line mode) +/- 3% output voltage regulation (economy line mode) +/- 10% output voltage regulation (battery mode) +/- 3% output receptacles (4) c13; (2) c19 included output power cables includes 2 c13 to c14 and 1 c20 to c19 output power cables load management receptacles two switchable single-outlet c19 load banks hot-swap pdu options pdubhv20 (2u / 6 c13, 2 c19 outlets) output ac waveform (ac mode) sine wave output ac waveform (battery mode) pure sine wave input rated input current (maximum load) 9.7a (200v), 9.3a (208v), 8.8a (220v), 8.5a (230v), 8.1a (240v) nominal input voltage(s) supported 200v ac; 220v ac; 230v ac; 240v ac ups input connection type c20 inlet ups input connection description c20 inlet accepts user-supplied ac power cord input circuit breakers 15a input phase single-phase battery full load runtime (min.) 5 min. (1600w) half load runtime (min.) 14 min. (800w) expandable battery runtime supports extended runtime with optional external battery packs external battery pack compatibility bp48v24-2u (limit 1); bp48v60rt-3u (multi-pack compatible); bp48v27-2us (multi-pack compatible) dc system voltage (vdc) 48 battery recharge rate (included batteries) less than 6 hours from 10% to 80% (typical, full load discharge) internal ups replacement battery cartridge rbc94-2u battery access front panel battery access door battery replacement description hot-swappable, user replaceable batteries voltage regulation voltage regulation description online, double-conversion power conditioning overvoltage correction 3% output voltage regulation during overvoltages to 275 3 / 6
undervoltage correction 3% output voltage regulation during undervoltages to 156 severe undervoltage correction 3% output voltage regulation during undervoltages to 130 (under 70% load only) user interface, alerts & controls switches 2 switches control off/on power status and alarm-cancel/self-test operation alarm cancel operation power-fail alarm can be silenced using alarm-cancel switch audible alarm audible alarm indicates ups startup, power-failure, low-battery, overload, ups fault and remote shutdown conditions led indicators 14 leds indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-led meter displays load and battery charge levels; led panel rotates for viewing in rack/tower formats surge / noise suppression ups ac suppression joule rating 660 ups ac suppression response time instantaneous emi / rfi ac noise suppression yes physical included mounting accessory description 4 post rackmount installation accessories included installation form factors supported with optional accessories 2 post rackmount (2postrmkitwm); wallmount (2postrmkitwm); tower (2-9ustand) primary form factor rackmount ups power module dimensions (hwd, in.) 3.5 x 17.5 x 19 ups power module dimensions (hwd, cm) 8.9 x 44.4 x 48.3 rack height (u spaces) 2 ups power module weight (lbs.) 47.5 ups power module weight (kg) 21.6 ups shipping dimensions (hwd / in.) 9 x 20.3 x 23 ups shipping dimensions (hwd / cm) 23 x 51.4 x 58.4 shipping weight (lbs.) 59.8 shipping weight (kg) 27.1 cooling method fan ups housing material steel environmental operating temperature range +32 to +104 degrees fahrenheit / 0 to +40 degrees celsius 4 / 6
storage temperature range +5 to +122 degrees fahrenheit / -15 to +50 degrees celsius relative humidity 0 to 95%, non-condensing ac mode btu / hr. (full load) 885.6 ac economy mode btu / hr. (full load) 347.2 battery mode btu / hr. (full load) 885.6 ac mode efficiency rating (100% load) 86% ac economy mode efficiency rating (100% load) 94% audible noise audible noise: 50dba at front side 1 meter communications communications interface usb (hid enabled); db9 serial; contact closure; epo (emergency power off); slot for snmp/web interface network monitoring port description supports detailed monitoring of ups and site power conditions; db9 port supports rs232 and contact closure communications poweralert software included communications cable usb and db9 cabling included watchdog compatibility supports watchdog application, os and hard-reboot restart options for remote applications line / battery transfer transfer time no transfer time (0 ms.) in online, double-conversion mode low voltage transfer to battery power (setpoint) 160v (100% load), 130v ( <70% load) high voltage transfer to battery power (setpoint) 275 special features cold start (startup in battery mode during a power failure) cold-start operation supported high availability ups features automatic inverter bypass; hot swappable batteries green energy-saving features high efficiency economy mode operation; individually controllable load banks; schedulable daily hours of economy mode operation certifications ups certifications ce; tested to saso (saudi arabia) ups certification details kuwait warranty 5 / 6
product warranty period (worldwide) 2-year limited warranty ? 2015 tripp lite. all rights reserved. all trademarks are the sole property of their respective owners. tripp lite has a policy of continuous improvement. specifications are subject to change without notice. photos may differ slightly from final products. 6 / 6


▲Up To Search▲   

 
Price & Availability of SUINT2200RTXL2UA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X